There are 2 methods which can be used to factory reset these devices, the web interface or by using the reset button on the unit.
Web Interface Instructions:            
	- Access the web interface by entering the Digi One IA/IAP Device?s IP Address in a browser?s URL window.                  
 
	- Log in to the Digi One IA/IAP Device.                  
 
	- From the main menu, choose Admin > Reset Config.                  
 
	- Choose Continue to reset the configuration to factory defaults.             
 
Hardware Instructions:                
	- Power off/uplug the device
 
	- Use a pen, the point of a paper clip, or some other device to press and hold the recessed button (located on the side of the Ethernet connector).                 
 
	- Power on/plug in the Digi One IA/IAP Device while holding in the reset button.                 
 
	- Continue to hold until a 1-5-1 LED pattern is displayed and the DIAGS LED goes out (or after 2 minutes if the Digi One IA/IAP is at a remote location), release the button.  
 
Note:  These methods will factory reset all setting on the unit including the network/IP address configuration and will revert login defaults to username:  root, password: dbps.
Last updated: 