When using the Digi USB JTAG-Link (P/N: DG-ACC-JLNK)
with an older revision of the Digi Connect (Wi-)ME (9210) development board, you might experience failure messages:
Could not perform target reset
Failed to connect.
Could not perform custom init sequence.
![User-added image](https://forms.na1.netsuite.com/core/media/media.nl?id=464210&c=818164&h=5cb50bab8291291565fc)
Known good development board has green silk screen number: 30006002
-06 REV A
Known bad development board has green silk screen number: 30006002
-05 REV A
fix: buy a new development board DC-ACC-DBME Revision E,
50000882-05 Revision D,
55001086-06 Revision A or newer